QUESTION 76: Do you support

Representation ID: 2076

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachment for full response.
Few or no constraints. Standard information required at a planning stage.
"1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): Yes - External Flooding
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised." The site is adjacent to a flow path. This must be considered in the site assessment.
Assessment: Green

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 19: Do you think

Representation ID: 2077

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

"1.] At risk of surface water flooding?:
* 3.33% AEP Event [Extent]:
* 3.33% AEP Event [Depth]:
* 1.0% AEP Event [Extent]:
* 1.0% AEP Event [Depth]:
* 0.1% AEP Event [Extent]:
* 0.1% AEP Event [Depth]:
2.] Internal & external flooding?:
* On-site:
* Within proximity to site (~500.00m):
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site:
* Within proximity to site (~100.00m):
4.] Surface water sewer systems?:
* On-site:
* Within proximity to site (~100.00m):
5.] Source Protection Zone?:
6.] Internal Drainage Board?:
7.] The site predominantly has superficial deposits of . Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 31: Do you think

Representation ID: 2078

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full comments.
Few or no constraints.
Standard information required at a planning stage.
At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: Minor flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: No
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 62: Do you support

Representation ID: 2079

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full response.
Mitigation required for heavy constraints. Significant information required at a planning stage.
"1.] At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: Moderate flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): Yes|Main river
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: No
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised." "The on-site flood risk is a moderate flow path in the 0.1% AEP event, dissecting the site south-north in the west of the site. Flow lines indicate this flood water flows north off of the site, contributing to a larger flow path west and north of the site. We advise this must be considered in the site assessment.
A large area of the site is unaffected by flood risk and has the potential to be developed."
Assessment: Amber

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 158: Do you think

Representation ID: 2080

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full comments.
Assessment: Green
Few or no constraints.
Standard information required at a planning stage. 1.] At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: Minor flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): Yes - Internal Flooding|Yes - External Flooding
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 98: Do you think

Representation ID: 2081

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full comments.
Few or no constraints.
Standard information required at a planning stage.
1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): Yes - External Flooding
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."

Assessment: Green

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 144: Do you support

Representation ID: 2082

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full response.
Few or no constraints. Standard information required at a planning stage.
"1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 49: Do you think

Representation ID: 2083

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full comments.
Few or no constraints.
Standard information required at a planning stage. 1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: Waveney Valley
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."

Assessment: Green

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 77: Do you support

Representation ID: 2084

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full response.
Mitigation required for heavy constraints. Significant information required at a planning stage.
"1.] At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: Minor flooding
* 3.33% AEP Event [Depth]: 0.00 - 0.30cm.
* 1.0% AEP Event [Extent]: Minor flooding
* 1.0% AEP Event [Depth]: 0.00 - 0.30cm.
* 0.1% AEP Event [Extent]: Moderate flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 2
6.] Internal Drainage Board?: Geldeston 1
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised." "The eastern side of the site partially intersects the Geldeston 1 IDB.

Part of the on-site flood risk forms a moderate flow path in the 0.1% AEP event, dissecting the site west-south in the west, southwest and centre of the site. Flow lines indicate this flood water flows south off of the site, contributing to a larger flow path south of the site. The on-site flow path forms a curve shape. We advise this must be considered in the site assessment.
A large area of the site is unaffected by flood risk and has the potential to be developed."
Assessment: Amber

Comment

South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)

QUESTION 47: Do you support

Representation ID: 2085

Received: 14/07/2021

Respondent: Norfolk County Council - LLFA

Representation Summary:

See attachments for full response.
We were unable to review this site as a cross-reference with the provided GIS information was not possible. We have highlighted this row as pink in our review table.

For instructions on how to use the system and make comments, please see our help guide.