South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
Search representations
Results for Norfolk County Council - LLFA search
New searchComment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 76: Do you support
Representation ID: 2076
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachment for full response.
Few or no constraints. Standard information required at a planning stage.
"1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): Yes - External Flooding
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised." The site is adjacent to a flow path. This must be considered in the site assessment.
Assessment: Green
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 19: Do you think
Representation ID: 2077
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
"1.] At risk of surface water flooding?:
* 3.33% AEP Event [Extent]:
* 3.33% AEP Event [Depth]:
* 1.0% AEP Event [Extent]:
* 1.0% AEP Event [Depth]:
* 0.1% AEP Event [Extent]:
* 0.1% AEP Event [Depth]:
2.] Internal & external flooding?:
* On-site:
* Within proximity to site (~500.00m):
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site:
* Within proximity to site (~100.00m):
4.] Surface water sewer systems?:
* On-site:
* Within proximity to site (~100.00m):
5.] Source Protection Zone?:
6.] Internal Drainage Board?:
7.] The site predominantly has superficial deposits of . Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 31: Do you think
Representation ID: 2078
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full comments.
Few or no constraints.
Standard information required at a planning stage.
At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: Minor flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: No
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 62: Do you support
Representation ID: 2079
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full response.
Mitigation required for heavy constraints. Significant information required at a planning stage.
"1.] At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: Moderate flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): Yes|Main river
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: No
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised." "The on-site flood risk is a moderate flow path in the 0.1% AEP event, dissecting the site south-north in the west of the site. Flow lines indicate this flood water flows north off of the site, contributing to a larger flow path west and north of the site. We advise this must be considered in the site assessment.
A large area of the site is unaffected by flood risk and has the potential to be developed."
Assessment: Amber
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 158: Do you think
Representation ID: 2080
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full comments.
Assessment: Green
Few or no constraints.
Standard information required at a planning stage. 1.] At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: Minor flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): Yes - Internal Flooding|Yes - External Flooding
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 98: Do you think
Representation ID: 2081
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full comments.
Few or no constraints.
Standard information required at a planning stage.
1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): Yes - External Flooding
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 144: Do you support
Representation ID: 2082
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full response.
Few or no constraints. Standard information required at a planning stage.
"1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: No IDB referenced
7.] The site predominantly has superficial deposits of DIAMICTON. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 49: Do you think
Representation ID: 2083
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full comments.
Few or no constraints.
Standard information required at a planning stage. 1.] At risk of surface water flooding?: No
* 3.33% AEP Event [Extent]: No flooding present
* 3.33% AEP Event [Depth]: No flooding present.
* 1.0% AEP Event [Extent]: No flooding present
* 1.0% AEP Event [Depth]: No flooding present.
* 0.1% AEP Event [Extent]: No flooding present
* 0.1% AEP Event [Depth]: No flooding present.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 3
6.] Internal Drainage Board?: Waveney Valley
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised."
Assessment: Green
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 77: Do you support
Representation ID: 2084
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full response.
Mitigation required for heavy constraints. Significant information required at a planning stage.
"1.] At risk of surface water flooding?: Yes
* 3.33% AEP Event [Extent]: Minor flooding
* 3.33% AEP Event [Depth]: 0.00 - 0.30cm.
* 1.0% AEP Event [Extent]: Minor flooding
* 1.0% AEP Event [Depth]: 0.00 - 0.30cm.
* 0.1% AEP Event [Extent]: Moderate flooding
* 0.1% AEP Event [Depth]: 0.00- 0.30cm.
2.] Internal & external flooding?:
* On-site: No
* Within proximity to site (~500.00m): No
3.] Watercourses [Online ordinary watercourses or mains rivers]?:
* On-site: No
* Within proximity to site (~100.00m): No
4.] Surface water sewer systems?:
* On-site: No
* Within proximity to site (~100.00m): No
5.] Source Protection Zone?: Source Protection Zone 2
6.] Internal Drainage Board?: Geldeston 1
7.] The site predominantly has superficial deposits of SAND AND GRAVEL. Comments on infiltration potential are dependent on a complete geotechnical investigation, including BRE365 Soakaway Testing. Where possible, surface water infiltration should be utilised." "The eastern side of the site partially intersects the Geldeston 1 IDB.
Part of the on-site flood risk forms a moderate flow path in the 0.1% AEP event, dissecting the site west-south in the west, southwest and centre of the site. Flow lines indicate this flood water flows south off of the site, contributing to a larger flow path south of the site. The on-site flow path forms a curve shape. We advise this must be considered in the site assessment.
A large area of the site is unaffected by flood risk and has the potential to be developed."
Assessment: Amber
Comment
South Norfolk Village Clusters Housing Allocations Plan (Reg. 18 Draft)
QUESTION 47: Do you support
Representation ID: 2085
Received: 14/07/2021
Respondent: Norfolk County Council - LLFA
See attachments for full response.
We were unable to review this site as a cross-reference with the provided GIS information was not possible. We have highlighted this row as pink in our review table.